<LOGO>
FM Transmitter Measurement Report
Created: 2024-12-30 15-30-03
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
97.40 MHz 5/5, 51 dBuV RIRE &
Pilot RDS Phase Difference
7.2 kHz 4.6 kHz No phase relation found.
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 0,0 kHz
MIN Hold Max. Samples at Total Samples % above 75,0 kHz
11 kHz 72 kHz 10020 0,0299
Modulation Power
Limit Measuring Tolerance
10,0 dBr 0,0 dBr
MIN AVE MAX % above 10,0 dBr
4,5 dBr 5,31 dBr 6,7 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
" RIRE & " F226 0 (No PTY) 1 0 1 2 15:29, 30.12.2024
RT
"RIRE : L APPEL TROP CON DE R&C "
AF EON
91.4, 92.0, 92.1, 94.4, 95.4, 96.2, 97.3, 97.4, 97.5, 97.6, 103.3, 104.4, 107.3 MHz -
FM Scope Station: 97.40 MHz, signal: 5/5 (50 dBuV) Max at: 72 kHz MIN: 11 kHz % above 75 kHz: 0,0299 Acquired: 2024/12/30 15:29:00 Total samples: 10020 Equivalent time: 0:08:21 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 1000 2000